Falcon 1200 Reflow Solder/Curing System
Typical Specification
| 1200SB | 1200WB | |
|---|---|---|
| Heating Zones | 7 | 7 |
| Cooling Zone | 2 | 1 |
| Load Zones | 1 | N/A |
| Total Number of Zones | 10 | 8 |
| Platen Size | 12.5 in. W X 13.5 in L. | 12.5 in W x 13.5 in L |
| Minimum Substrate Size | N/A | 3 inches |
| Maximum Substrate Size | 12 in. W X 12 in. L x 0.9 in. H | 12 in W x 12 in L |
| Weight Limit | N/A | Approx. 2.5 lbs |
| Speed Mode (Inches per Minute | 1 in. to 80 in. per min. | N/A |
| Time Mode (Dwell & travel Time) | 15 sec. To 99 min. 59 sec. (per Zone) | 16 sec. – 99 min, 59 sec. |
| Temperature (Standard) | Up to 420°C | Up to 420C |
| Temperature Accuracy | ±2°C | +/- 2C |
| Warm-up Time to 230°C | 15 minutes (approx.) | 15 min. approx. |
| Coolant Flow | 0.5 to 2 GPM | .5 to 2 GPM |
| Alarms | Over/Under Temperature, Gas Flow, Coolant Flow & Temperature, Motor Torque, SMEMA (or other) Interface | Over/Under Temperature, Gas Flow, Coolant Flow and Temperature, Motor Torque, SMEMA (or other) Interface |
| Parts Flow (Specify) | In-line: L to R or R to L | L to R or R to L |
| Gas consumption | 0-800 cubic feet/hour (process dependent) | 1200 CFH |
| O2 Level | <25 PPM (process dependent) | <25 PPM (process dependent) |
| Voltage (Specify) | 200-240 VAC, 50-60 HZ, 3 phase | 200-240 VAC, 50-60 Hz, 3 Phase |
| Start-up Power | 33 Kw @ 240 VAC | 33 kW @ 240 VAC |
| Power Consumption | 50% duty cycle or less (process dependent) | 50% duty cycle or less (process dependent) |
| Basic Unit Weight | 1000 lbs. | 1000 lbs |
| Basic Unit Dimensions | L 164 x W 24 X H 45 inches | L 178 x W 24 x H 45 inches L 178 with paddle adapters |